Residual air volume meter for cooling systems

  • Residual air volume meter for cooling systems
Premium Produkt Auszeichnung

item number :
RLM 01_LR (011450_1)
GTIN :
4251712706391

Description

Measuring principle

  • Air is compressible. Liquids are (almost) incompressible. RLM 01_LR doses the coolant through the expansion tank in very small (volume) steps.
  • Each dosing step leads to an increase in pressure in the test object.
  • The measuring arrangement records the change in volume and the increase in pressure.
  • The measurement error of the RLM is 01_LR
    • ≤± 3% (related to the real residual air volume)
    • << 1% (related to the ratio of the volume of the test object to the residual air)

Measurement process

  • Measuring arrangement [cooling system/thermal management system] must have cooled down to rule out undesired temperature effects. [Tmax 30°C].
  • Measuring arrangement [cooling system/ thermal management system] is completely filled.
  • RLM 01_LR meters the coolant mixture into the expansion tank.
  • At the same time, the increase in pressure is measured.
  • The measuring process takes place automatically and is completed within 2 minutes.

Service

  • It can be operated either via an (optional) industrial PC 10" touch screen or via a customer computer.

Software

  • RLM 01_LR software is part of the scope of delivery and is license-free.

Access rights

  • ADMIN can create and execute test routines (via user software).
  • USER can only execute check routines. Test routines run automatically.
  • USER has no possibility to intervene in the test routines.

Documentation

  • The measured values ​​can be documented in pdf format. Output via USB port.

Technical specifications

  • Max. volume measurement: 1,400 ml cm³ [residual air]
  • Coolant reservoir: 10 L
  • Power supply: 230 VAC @ 50 Hz
  • Weight: 13kg
  • Dimensions: H x W x D: 270 x 450 x 600 cm
Scope of delivery
  • RLM 01_LR
  • RLM 01_LR software
  • trolley
  • 10 L storage tank

Cookie settings
This website uses cookies that enable you to use services offered by external providers, such as YouTube or Google Maps. The legal basis here is Art. 6 DSGVO (1) a.

Here you can object to the anonymized recording of your user behavior by MATOMO. For this purpose, we store a cookie on your computer to respect this decision also on subsequent visits.

Please note that depending on your settings, some functions may not be available.

You can find more information in our Privacy policy

Matomo settings

Attention: When you object to tracking, a Matomo deactivation cookie is set that remembers your objection.